RT4-02F controller is used for phase I composting in open or half-open bunkers with roof. In automatic mode the controller calculates average compost temperature by three points and compares it with a set-point. By the difference between a current average and set temperature, as well as depending on ambient temperature, the controller generates an output signal to control the fan. The controller also has a built-in timer for setting a period and time of the fan activation in manual control mode.
RT4-02F can be connected to PC via RS485 communication interface.
TechnologSoft Musroom Edition software enables control of environmental parameters and displays all alarm situations on your PC.
Functions
- Inlet air temperature measurement
- Compost temperature measurement in three points
- Calculation of average compost temperature by three temperature probes
- Automatic control of fan actuation time within the set limits (fan works ON/OFF only, no VFD control)
- Setting fan mode (manual or automatic)
- Nonvolatile time relay
- 24-hours archive of main parameters with 30 min interval
- Alarm signaling of probe failure and temperature deviation
- Data transfer to PC via RS485 communication interface
- Remote PC control
Basic Specifications
| Temperature Range | 0 to 100°С |
| Temperature Accuracy | 0.2°C |
| Power Consumption | max 3 W |
| Supply Voltage | 90 to 242 VAC |
| Protection Class | IP54 |
| Panel Board Dimensions (HxWxD) | 96х96х70 mm |
| Weight | max 0.6 kg |